14 connecting pos (point of sales), Connecting pos (point of sales), Rs232 cable – AVerMedia Technologies NV 6000 EXP User Manual

Page 34: Chapter 2 hardware installation, C. coil ratings (at 20 oc ), D. contact ratings, Avermedia

Advertising
background image

Chapter 2 Hardware Installation

25

C. COIL RATINGS (at 20 oC )

Coil Nominal Voltage

(VDC)

Coil Resistance

10%

Pick-up Voltage

(VDC)

Drop-Out Voltage

(VDC)

Nominal Current

(mA)

5

125

3.75

0.5

40

* Max Continuous Voltage at 20

o

C : 110% of Coil Nominal Voltage

D. CONTACT

RATINGS

Contact Arrangement

1 Form C (SPDT)

max. Switch Power

max. Switch voltage

max. Switch current

125VA 60W

125VAC 30VDC

1A

Contact Resistance

≤ 100mΩ

Resistive Load

1A/125VAC

1A/30VDC

2.14 Connecting POS (Point of Sales)

AVerMedia

®

AVerDVR can be integrated with POS system equipment. Connecting the POS

equipment to AVerMedia

®

AVerDVR system thru RS232 connection, enables you to view,

record and keep track of the items that were sold. You may also select the camera on where to
display all the data.
To connect, locate the RS232 port of the POS equipment and PC. Use an RS232 cable (not
supplied) to make the connection.

RS232 cable

i

For detail of POS installation, please refer to POS Quick Guide.

Advertising