Alliance Laundry Systems UX18PVQM7 User Manual

Page 20

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Operation

9001001

18

If there was a problem during heating in a step at the
end of the program, the control will show
“Temperature sensor error”. The temperature was
never reached in this cycle.

Possible Faults:

Bad temperature probe.

Wiring to electrical or steam heating relay has
failed.

Electrical heating elements or steam valve is
broken.

NOTE: If the cycle aborted, it may be due to a
temperature sensor error.

The control did not sense any pulses or the control
sensed wrong pulses from the rpm sensor.

Possible Faults:

Rpm sensor is broken.

Distance from rpm sensor to pulley is too large
(>2mm).

Bad motor.

V-belt is broken.

Problems with the inverter.

Wiring connection is bad.

An error occurred at the end of a spin stop or during
coast down, where the rpm sensor suddenly failed to
give output pulses.

Possible Faults:

Rpm sensor failure.

Rpm sensor dislocated (too far from pulley).

Broken V-belt.

Wiring disconnected.

Rotation
sensor error

Speed detection
error

Temperature
sensor error