Names of parts, Operation mechanism, Indoor unit u1 type – Panasonic S106MF2E5A User Manual

Page 5: T2 type, F2 type, Optional

Advertising
background image

5

E

NGLISH

Names of Parts

Air outlet

Air outlet duct *

Air-outlet grille *

Suspension bolt *

Bolt anchor *

Ceiling material *

Indoor unit

Operation Mechanism

„

Heating performance

z

Since this air conditioner utilizes outside air for heating,

its heating performance deteriorates as outside tempera-

ture decreases.

(Due to heat pump system)

→In that case, use another heating appliance.

„

Defrosting

z

This appliance may start defrosting operation to melt

frost formed in the outdoor unit.

1

Defrosting starts

: The indoor unit fan stops (or the

speed becomes extremely slow).

→” ” (STANDBY) appears.

2

Heating operation resumes after several

minutes

: The indoor unit fan remains stopped (or

it will run at a very slow speed) until the indoor heat

exchanger coil warms up suffi ciently.

→ ” ” (STANDBY) is shown.

3

Defrosting is complete

: The indoor unit fan starts

operation.

→ ” ” (STANDBY) disappears.

INDOOR UNIT

U1 type

(4-Way Cassette)

Water drain

Ceiling panel

(optional)
Air outlet

(4 locations)
Air intake grille

(air intake)

„

‘‘DRY’’ operation

z

Once the room temperature reaches the level that was

set, the outdoor unit repeats the cycle of turning on and

off automatically.

z

When the outdoor unit is turned off, the indoor unit fan

will stop, too.

(To prevent the humidity in the room from rising again)

z

When the room temperature is more likely to reach the

level that was set, the fan speed is set to ‘‘breeze’’ (light

wind) automatically.

z

‘‘DRY’’ operation is not possible if the outdoor tempera-

ture is 15 °C or less.

„

Should the power failure occurs while the

unit is running

When the unit automatically resumes operation after

temporary power failure, it uses the same settings before

the power was cut off.

Air intake grille

(air intake)

Water drain

* Field supplied

T2 type

(Ceiling)

F2 type

(Low Silhouette Ducted)

Model No.

CZ-RWSU2 (U1 type)

CZ-RWST3 (T2 type)

CZ-RWSC3

(For all indoor units)

Optional

Wireless Remote Controller

Model No.

CZ-RTC2

For all indoor

units

Timer Remote Controller

Model No.

CZ-RTC3

For all indoor

units

Read the operating instructions included with the Remote Controller.

High-spec Wired Remote Controller

OI_F569617_EU_L.indb 5

2013-12-17 17:57:39

Advertising