VI

. ACCESSORIES

Use only suitable size of bit.

Panasonic original Optional Quick change chuck (EY9HX110E).

Chuck Size: 6.35 mm (1/4”) hex

VII

. APPENDIX

MAXIMUM RECOMMENDED CAPACITIES

Model

EY7546

EY7547

EY7550

EY7551

Screw driving

Wood screw

3.5 mm - 9.5 mm

Self-drilling screw

3.5 mm - 6 mm

Bolt fastening

Standard bolt:M6-M16

High tensile bolt : M6 - M12

2) Tightening time

Longer tightening time results in increased

tightening torque. Excessive tightening,

how ever, adds no value and reduces the

life of the tool.

3) Different bolt diameters

The size of the bolt diameter affects the

tight ening torque.

Generally, as the bolt diameter increases,

tightening torque rises.

4) Tightening conditions

Tightening torque will vary, even with the

same bolt, according to grade, length, and

torque coefficient (the fixed coefficient indi-

cated by the manufacturer upon produc-

tion).

Tightening torque will vary, even with

the same bolting material (e.g. steel),

accord ing to the surface finish.

Torque is greatly reduced when the bolt

and nut start turning together.

5) Socket play

Torque is lowered as the six-sided configu-

ration of the socket of the wrong size is

used to tighten a bolt.

6) Switch (Variable speed control trigger)

Torque is lowered if the unit is used with

the switch not fully depressed.

7) Effect of Connecting Adaptor

The tightening torque will be lowered

through the use of a universal joint or a

connecting adaptor.

EY7551

M8, M10 x 35 mm. M12 x 45 mm

High tensile bolt

196.0

(2000)

147.0

(1500)

98.0

(1000)

49.0

(500)

0.5

0.0

1.0

1.5

2.0

2.5

3.0

M12

M10

M8

N

s

m

(k

gf-cm)

Tightening torque

Tightening time (Sec.)

Bolt

Nut

Washer

Steel plate

thickness 10 mm (3/8")

Washer
Spring washer

Tightening conditions

• The following bolts are used.

Standard bolts: Strength type 4.8

High tensile type 12.9

4.8

Explanation of the strength type

Bolt yield point

(

80

% of tensile strength)

32

kgf/mm

2

(45000 psi)

Bolt tensile strength

40

kgf/mm

2

(56000 psi)

EY7546_EY7547_EY7550_EY7551_EU.indb 13