- 1 -

• You can select from 30 torque clutch

settings (1 to 30).

• Use figures from the Tightening Torque

Chart to guide your selection of torque
clutch setting. (See the following tighten-
ing torque chart)

. Press the OK button to accept the select-

ed torque clutch setting.

• The control panel will stop flashing and

light up.

CAUTION:

• You must press the OK button in order

for the selected setting to take effect.

• Be sure to verify the new value after

changing the setting. (See page 14.)

Setting the snug point detection level

()

(3)

(1)

1. Press the torque setting mode button.

• The snug point detection level setting

value will be displayed.

Display

Battery indication lamp

. Press the

and

buttons to set the best

snug point detection level for the work
you’re performing.

Display

Snug point detection level

L1

Low

(Use for work characterized by

low loads before the snug point

is reached.)

L

High

(Use for work characterized by

high loads before the snug point

is reached.)

3. Press the OK button to accept the number

of torque stages and the snug point detec-
tion level.

• The tool’s panel will flash and then light

up continuously.

CAUTION:

• Set the snug point detection level from

“L1.” Setting the snug point detection level
from “L” may result in cracking or defor-
mation of the target material.

• If the tool stops before the snug point at

snug point detection level “L1,” set the
snug point detection level to “L.”

• Changing the snug point detection level

from “L1” to “L” may increase the torque.
Set the number of torque stages again
after making this change.

• The setting will not be changed until

you press the OK button.

• After changing the setting, be sure to check

the new setting value. (See page 14.)

IMPORTANT INFORMATION:

• You can set the snug point detection

level and retightening prevention time at
the same time by changing the retight-
ening prevention time (see page 13)
before pressing the OK button and then
pressing the OK button.

• Pressing the torque setting mode but-

ton toggles the display between the
snug point detection level setting value
and the number of torque stages set-
ting value.

• The tool ships with the snug point

detection level set to “L1.”

• When the number of torque stages has

been set as shown below, the snug
point detection level cannot be switched
from “L1” to “L.”

Model

Number of torque stages

setting

EZFLA4

1 to 8

EZFLA5

1 to 3

Advertising