Panasonic EYFMA1J User Manual

Page 14

Advertising
background image

- 14 -

Radio signal range limitation function
on/off setting (EYFLA4AR, EYFLA5AR,
EYFLA5QR, EYFLA6PR)
1. Set the tool to configuration mode.

(See page 11.)

. Press the format button.

• The control panel will begin flashing.

Display: The letter “F” flashes on and off.
Battery indication lamp: The upper and

lower bars of the battery flash on and off.

Display

Battery indication lamp

3. Press the format button again.

• Radio signal range limitation function

on/off setting value will be displayed.

4. Press the

and

buttons to set radio

signal range limitation function on/off.

Display

Radio signal

range limitation

function mode

Status

C0

OFF

Tool is operational in the
absence of communica-
tions with the Assembly

Qualifier.

C1

ON

Tool is not operational
in the absence of com-
munications with the As-

sembly Qualifier.

Factory settings

• Radio signal range limitation function

setting: C0 (OFF)

NOTE:

• For more information about how to register

the tool and assembly qualifier, see the
assembly qualifier instruction manual.

Initializing All Settings

Factory settings

• Torque clutch setting: “F” (torque con-

trol function off)

• Interval setting: 0 (off)

• This section explains how to revert all tool

settings to their default values at the time of
shipment from the factory.

• The error display will be turned off.
1. Set the tool to configuration mode.

(See page 11.)

. Press the format button.

• The control panel will begin flashing.

Display: The letter “F” flashes on and off.
Battery indication lamp: The upper and

lower bars of the battery flash on and off.

Display

Battery indication lamp

3. Press the OK button to accept the select-

ed setting.

• The control panel will stop flashing and

light up.

Checking Tool Settings

• This section describes how to have the

tool display current settings for approx-
imately 3 seconds when the tool is
stopped.

• You cannot check tool settings when the

control panel is turned off. First, engage
the switch briefly to reactivate the display.

Checking the sung point detection setting
1. Press the torque set button.

• Control panel display

Display: The torque set lights up.
Battery indication lamp: The upper and mid-

dle bars of the battery flash on and off.

Checking the interval
1. Press the interval set button.

• Control panel display

Display: The interval set lights up.
Battery indication lamp: The middle bar

of the battery flashes on and off.

Advertising
This manual is related to the following products: