12 full/dribble batch function – A&D Digital Platform Scales HW-10KGV User Manual

Page 34

Advertising
background image

HW-G Instruction Manual Page 32

HW-G OZIM v1a

12 Full/Dribble Batch Function

This function changes the scale to a filling machine which sub-divides a bulk product like
grain into loads of predetermined and virtually constant mass.

It is necessary to set the parameter of the “comparator function (

f6 9

)”, “ full/dribble

batch sub-function (

f10 0

~

f10 3

)” in the function table, final value (HI), preliminary

value (OK) and zero band (LO) in advance to use this function.

It is necessary to install option OP-03 or OP-04, if you use the relay output of the full/
dribble batch function.

In the example of a filling machine with a scale and hopper, the performance and
processing of the system are assumed to be as follows:

Zero Band

Preliminary value Final value

indicator/

indicator/

indicator/

LO relay output OK relay output

HI relay output

Gross < Zero band

(Zero detection level)

ON/Make

OFF/Break

OFF/Break

Net < Final - Preliminary

OFF/Break

ON/Make

ON/Make

Final - Preliminary < Net < Final

OFF/Break

OFF/Break

ON/Make

Final < Net

OFF/Break

OFF/Break

OFF/Break