3. Steam Damper Air System Connections

The ADS-78 is manufactured with a pneumatic (piston) damper system, which requires an external supply
of compressed air. The air connection is made to the steam damper solenoid valve, which is located at the
rear inner top area of the dryer just in front of the electric service relay box.

a. Air Requirements

b. Air Connection

Air connection to system --- 1/8” N.P.T.

c. Air Regulation

No air regulation or filtration is provided with the dryer. External regulation and filtration of 80 PSI (5.51
bar) must be provided. It is suggested that a regulator/filter gauge arrangement be added to the
compressed air line just before the dryer connection. This is necessary to ensure that correct and clean
air pressure is achieved.

MAN2497

COM PRESSED

AIR SUPPLY

AIR PRESSURE

Normal

80 PSI

5.51 bar

Minimum Supply

70 PSI

4.82 bar

Maximum Supply

90 PSI

6.21 bar

Shaded areas are stated in metric equivalents