6.5 Electrical Wiring

W

HILE THE

ECA

WIRING REQUIREMENTS ARE VERY SIMPLE

,

ALWAYS KEEP IN MIND THAT ACCESS

TO THESE CONNECTORS REQUIRES THE REMOVAL OF THE COVER

,

AND AS SUCH THIS PROCEDURE

SHOULD ONLY BE PERFORMED BY A TRAINED PROFESSIONAL

.

Wait a minimum of 3 minutes after disconnecting power before servicing the ECA or
pump motor. Capacitors retain a charge even after power is removed from the controller.

It is highly recommended that you take a step-by-step approach to wiring and confirming proper
ECA operation:

1. Make the Line voltage connections. These will allow you to operate the ECA and

attached Pulsafeeder pump.

2. Decide which low voltage Inputs and Outputs (e.g., 4-20mA in) will be used and make

those connections

3. Power-up and test the ECA to confirm the connections and check for proper operation.


6.6 Power Wiring Information

T

HESE PROCEDURES REQUIRE REMOVAL OF THE ENCLOSURE COVER

.

T

HIS SHOULD BE DONE ONLY IF

THE AREA IS KNOWN TO BE SAFE FOR ELECTRONIC WORK

.

Verify the correct supply voltage (115VAC or 230VAC) with the nameplate affixed to

your ECA. Ensure that your supply voltage matches the ECA configuration.

Wires should be routed within the enclosure in a manner that maintains separation

between line voltage and extra-low voltage conductors.

Applicable national and local electrical codes take precedence over

recommendations in the table below.

A circuit breaker or fuse must be provided as noted below.