End Point Set Up procedure

1. Press [MENU] to enter the {–MENU–} sub-system. Press [UP] or [DOWN] until {–MENU– / END

POINT} is displayed.

2. Press [ENTER] to display the {STROKE END POINT / MINIMUM = XXX%} screen.

STROKE END POINT

MINIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept your setting.

3. The {STROKE END POINT / MAXIMUM = XXX%} screen is displayed.

STROKE END POINT

MAXIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept the setting.

4. The {SPEED END POINT / MINIMUM = XXX%} screen is displayed.

SPEED END POINT

MINIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept the setting.

5. The {SPEED END POINT / MAXIMUM = XXX%} screen is displayed.

SPEED END POINT

MAXIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept the setting.

6. The {PRIORITY SPEED} screen is displayed.
7. Press [UP] or [DOWN] to set the priority to either {SPEED} or {STROKE}.

PRIORITY

SPEED

-or -

PRIORITY

STROKE

Press [ENTER] to accept your selection.

8. The {FLOW RANGE} screen is displayed. This represents the available Flow Range based on your

settings. Press [ENTER]

FLOW RANGE

1.0% – 90.0%

9. The {CONFIRM CHANGE} screen is displayed.

CONFIRM CHANGE

YES

If you do not want to confirm these changes, press [DOWN] to display the {CONFIRM CHANGE =
NO} screen.

CONFIRM CHANGE

NO

In either case confirming or not confirming, press [ENTER] to complete the action.
At this point, you are returned to the {–MENU– / END POINT} screen.

7.2.9 Leak Detection Failure Set Up

This sub-menu allows you to configure the DLCM to interact with a PULSAlarm Leak Detection
Diaphragm. You can modify the way the DLCM responds to a diaphragm rupture. The following
responses are available:

Shut the motor off,

Trigger an alarm relay,

Shut the motor off and trigger an alarm relay,

Have no interaction with the Pump Motor or Alarm Relay other than log the diaphragm failure
and display a message on the LCD display (this message is displayed until a key on the keypad is
pressed).