End Point Set Up procedure

1. Press [MENU] to enter the {–MENU–} sub-system. Press [UP] or [DOWN] until {–MENU– / END

POINT} is displayed.

2. Press [ENTER] to display the {STROKE END POINT / MINIMUM = XXX%} screen.

STROKE END POINT

MINIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept your setting.

3. The {STROKE END POINT / MAXIMUM = XXX%} screen is displayed.

STROKE END POINT

MAXIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept the setting.

4. The {SPEED END POINT / MINIMUM = XXX%} screen is displayed.

SPEED END POINT

MINIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept the setting.

5. The {SPEED END POINT / MAXIMUM = XXX%} screen is displayed.

SPEED END POINT

MAXIMUM = XXX%

Press [UP] or [DOWN] to set the value. Press [ENTER] to accept the setting.

6. The {PRIORITY SPEED} screen is displayed.
7. Press [UP] or [DOWN] to set the priority to either {SPEED} or {STROKE}.

PRIORITY

SPEED

-or -

PRIORITY

STROKE

Press [ENTER] to accept your selection.

8. The {FLOW RANGE} screen is displayed. This represents the available Flow Range based on your

settings. Press [ENTER]

FLOW RANGE

1.0% – 90.0%

9. The {CONFIRM CHANGE} screen is displayed.

CONFIRM CHANGE

YES

If you do not want to confirm these changes, press [DOWN] to display the {CONFIRM CHANGE =
NO} screen.

CONFIRM CHANGE

NO

In either case confirming or not confirming, press [ENTER] to complete the action.
At this point, you are returned to the {–MENU– / END POINT} screen.

7.2.9 Leak Detection Failure Set Up

This sub-menu allows you to configure the DLCM to interact with a PULSAlarm Leak Detection
Diaphragm. You can modify the way the DLCM responds to a diaphragm rupture. The following
responses are available:

−

Shut the motor off,

−

Trigger an alarm relay,

−

Shut the motor off and trigger an alarm relay,

−

Have no interaction with the Pump Motor or Alarm Relay other than log the diaphragm failure
and display a message on the LCD display (this message is displayed until a key on the keypad is
pressed).