Camera cmd – Vaddio Panasonic AW-HE-100 Protocol User Manual
Page 5
Control and
Response to control
Response to Confirmation
E300/A
E600
E800
E800A
E350
E650
E655
E750
E860
HE100
HC1500
00
01
---
AW-E300
AW-E300P
AW-E300E
AW-E600
AW-E600P
to Ver.055
Returns model No. by
ASCII
Ex. OID:AW-E800P
from Ver.056
V1.00L01
Ver.1.00
-00-0.00
SOFTWARE
VERSION
QSV
OSV:[Data]
Software Version
V1.00L01
Ver.1.00
-00-0.00
AWC/AWB SET
OWS
OWS
ER3:OWS
---
AWC/AWB Start
AWC/AWC OK
AWC/AWB NG
---
Response Command
returns when AWC/AWB
finish
V1.00L01
Ver.1.00
-00-0.00
ABC/ABB SET
OAS
OAS
ER3:OAS
---
ABC/ABB Start
ABC/ABB OK
ABC/ABB NG
---
Response Command
returns when ABC/ABB finish
V1.00L01
Ver.1.00
-00-0.00
AWC MODE
QAW
OAW:[Data]
0
1
2
3
4
5
ATW
AWC A
AWC B
ATW
PRESET 3200K
PRESET 5600K
ATW
---
AWC A
AWC B
PRESET 3200K
PRESET 5600K
Be careful because Data
of control and question
is different.
V1.00L01
---
DETAIL
QDT
ODT:[Data]
0
1
2
0
1
2
V1.00L01
Ver.1.00
-00-0.00
GAIN UP
QGU
OGU:[Data]
00
01
08
-
11
-
1A
-
26
27
28
80
08
-
14
15
16
17
18
19
1A
80
above 18dB,
from Ver.188
above 18dB,
from Ver.188
above 18dB,
from Ver.056
Ver.001
V1.00L01
---
SHUTTER
QSH
OSH:[Data]
0
3
5
6
7
8
9
A
B
C
V1.00L01
---
Remarks
---
to Ver.187
Ver.001
Ver.001
OFF
1/100(NSTC)
1/120(PAL)
1/250
1/500
1/1000
1/2000
1/4000
1/10000
Synchro-Scan
ELC(AUTO ND)
Ver.001
from Ver.188
Ver.001
Ver.001
Ver.001
Ver.001
AGC Low -> Max Gain=18dB
AGC High -> Max Gain=30dB
if use AGC ON, Max Gain of AGC is set up by the AGC MAX
command(OSD:69).
Ver.001
AGC Low
AGC High
0dB
-
9dB
-
18dB
-
30dB
N/Eye Low
N/Eye
N/Eye High
AGC ON
AW-HE100
0dB
-
12dB
ER3
ER3
15dB
ER3
ER3
18dB
AGC ON
Data Contents
Data
Confirmation
Command
Control Command
ITEM
OID:[Data]
QID
MODEL NUMBER
Reply for
Confirmation
Command
Reply for
Control Command
---
Convertible
OFF
LOW
HIGH
HC1500, HE100
OFF
ON
ON
OAW:[Data]
ODT:[Data]
OGU:[Data]
OSH:[Data]
---
---
---
Camera Command([STX][Command][ETX])