Vaddio Panasonic AW-HE-100 Protocol User Manual

Page 4

Advertising
background image

(5)Pattern 5 (Other Menus)
In order of Command, ":", Number Command(2 Bytes), ":", Data. Data length=2 Bytes.
[STX] O S D : ? ? : ? ? [ETX]
H'02 H'4F H'53 H'44 H'3A H'** H'** H'3A H'** H'** H'03
In this pattern, numbers at rear part of command (6th and 7th letters) are the command and Data follows by 2bytes (9th and 10th letters)

(6)Pattern 6 (Questions to Camera)
There is only Command, not Data
[STX] Q ? ? [ETX]
H'02 H'51 H'** H'** H'03
This Command requires the programmed number of the Camera and Camera returns adding Data.
Data is 2 Bytes but there are same exceptions. It is specified as Q(H'51) -> O(H'4F).

(7)Pattern 7 (Questions to Camera 2)
In order of Command, ":", number of Command. No Data. Command from Camera is with Data.
[STX] Q S D : ? ? [ETX]
H'02 H'51 H'53 H'44 H'3A H'** H'** H'03
This Command also requires the programmed number of the Camera and the Command is converted into numbers. It can be programmed only by Cam
a) PC -> CAMERA
[STX] Q S D : 1 4 [ETX]
H'02 H'51 H'53 H'44 H'3A H'31 H'34 H'03
b) CAMERA -> PC
[STX] O S D : 1 4 : 1 4 [ETX]
H'02 H'4F H'53 H'44 H'3A H'31 H'34 H'3A H'31 H'34 H'03

(8)Pattern 8 (Related to Contact Closer P/T)
There is only Command, not Data
[STX] H ? ? [ETX]
H'02 H'48 H'** H'** H'03
Command for Lens I/F Card (AW-PB308) and control of lens for AW-E655. Camera repeats the same Command.

Camera Command([STX][Command][ETX])

4/26