Carefully remove and identify the following parts for the WallVIEW CCU HD1 system:

 One (1) - Sony EVI-HD1 High Definition PTZ Camera

 One (1) - Vaddio EZCamera Interface Module CCU (EZIM CCU)

 One (1) - Vaddio EZIM CCU to HD Break Out Cable

 One (1) - Vaddio Quick-Connect CCU Universal (1-RU Rack Mountable)

 One (1) - Vaddio HD1 Wall Mount

 One (1) - Sony IR Remote Control

 One (1) - EZCamera Control Adapter (RJ-45 to DB-9)

 One (1) - 36V PowerRite Power Supply with AC Cord Set

 One (1) - 2-position Phoenix Connector for Tally

 Mounting

Hardware

 Documentation

Vaddio

Manual

Sony EVI-HD1 Manual


Optional Accessory:
SD Break Out Cable, Part Number 440-6207-000

(Female BNC to Male RCA adapter not included)

Wiring Diagram Example:



































Figure 2:

The Quick-Connect CCU System uses a Cat. 5 (all 4-pairs) for power to ensure the motors receive the required

current to operate properly. The Video Cat. 5 cable uses all four pairs for video. The RS-232 Cat. 5 provides communication
to the camera for CCU and PTZ control and G/L (where applicable) to the camera. These Cat. 5 cables can be run up to 500’
(152.4m). See Appendix 1 for wiring and pin-out information. NOTE: A direct RS-232 Cat. 5 cable is required for each
Quick-Connect CCU and camera. Daisy-Chain configurations are not supported.

CAT-5 Cables

up to 500’

HD Break-out

Cable

EZIM CCU

Power

RS-232

HD or SD Video on CAT-5

RS-232 Tally

ProductionVIEW™ HD

HD VIDEO OUT (Y, Pb, Pr)
RS-232 IN
SD VIDEO OUT
G/L (Not Used)
POWER

Quick-Connect CCU

EVI-HD1 Camera, Wall Mount
with EZIM CCU

Component HD

+