Vaddio WallVIEW CCU HD1 User Manual

Page 5

Advertising
background image

WallVIEW CCU HD1

WallVIEW CCU HD1 Installation and User Guide 341-719 Rev. D

Page 5 of 12

INSTALLATION
All WallVIEW products are specifically designed for installation on a vertical wall surface with Cat. 5 cable
connectivity for Power, Video and Control signaling. Installation is simplified in that no custom 8-Pin mini-din
cables or expensive S-Video plenum cables are needed and no power outlets are required near the camera
bracket. All cabling is routed to the head-end using Cat-5 cables.

Before Installing

 Find the appropriate camera mounting location, paying close attention to camera viewing angles, lighting

conditions, possible line of site obstructions, and checking for in-wall obstructions where the camera is to
be mounted. Pick a mounting location to optimize the performance of the camera.

 Pre-wire all cabling as required (see wiring diagram examples).

 The Thin Profile Wall Mount for the WallVIEW CCU HD1 can be mounted directly to a 2-gang wall box or

can be mounted to drywall using four dry wall anchors.



MOUNTING INSTRUCTIONS

Step 1:
After determining the optimum location of the camera system, mark locations for the four screw holes and
cable pass-thru (vertical oval). Install the drywall mounts and cut the hole for the cable pass-thru. At this
point, do not install the Wall Mount.










Step 2:
Install the wall mounting hardware, unless installation will be to a 2-gang electrical box.


















Step 3:
Take the Wall Mount, and place it against the drywall anchors or 2-gang wall box, making sure to pull the Cat.
5 cables through the oval pass-through hole. Finger-tighten the screws down to the mount and confirm that
the base is level. Tighten the screws down firmly once the wall mount is level. If the bracket is to be
mounted on a 2-gang wall box, use the screws supplied with the electrical box.

Figure 3:
Thin Profile Wall Mount with oval cable feed-
through hole. The wall mount may be mounted
directly to a 2-gang wall box or to drywall with the
appropriate wall anchors.

Figure 4:
25-pin connector mounted to
EZIM CCU (left) and EZIM
CCU mounted to the Wall
Mount (right)

Advertising