Electrical requirements – Wittco 200-4R-BI User Manual

Page 6

Advertising
background image

DRAWER & CHIP WARMERS

F-41015 (03-14)

5

Please refer to the Electrical

Requirements in the Installation &
Operation Manual.”



6. Slide/install Warmer into
wall/cabinet

opening.


7.

Reinstall drawer assemblies into

warmer – Top to Bottom


ELECTRICAL REQUIREMENTS

ELECTRICAL CODES & STANDARDS:

The warmer must be installed in
accordance with:

In the United States of America:
1.

State and Local Codes.

2.

National Electrical Code, ANSI/

NFPA-70 (latest edition.) Copies

may be obtained from: The

National Fire Protection

Association, Batterymarch Park,

Quincy, MA 02269.


In Canada:
1. Local

Codes.

2.

Canadian Electrical Code, CSA

C22.1 (latest edition.) Copies

may be obtained from: The

Canadian Standard Association,

178 Rexcale Blvd., Etobicoke,

Ontario, Canada M9W 1R3.


ELECTRICAL CONNECTIONS:
The warmer is factory wired for either
110/120 volt or 208/240 volt, single
phase operation. All 110/120 volt
warmers are equipped with a 8 foot cord
and NEMA 5-15 plug as standard
equipment. All 208/240 volt warmers
are equipped with a 8 foot cord and
NEMA 6-15 plug. Refer to wiring
diagrams in the back of this manual.

The cord and plug supplied is a suitable
durable cord with a molded three-prong
plug, and is provided with a proper
strain relief.

All warmers are

equipped with a three-prong plug. It
is imperative that this plug must be
connected into a properly grounded
three-prong receptacle. If the
receptacle is not the proper
grounding type, contact an
electrician. DO NOT REMOVE THE
GROUNDING PRONG FROM THIS
PLUG.

Verify that the power source
matches the Serial Data Plate located
on the lower back corner of the
warmer and the plug configuration
before the connection is made.

(Fig. 1)

SERIAL DATA PLATE

Fig. 1



Advertising