Operation, Controls, Operating instructions – Wittco 200-4R-BI User Manual
Page 7
 
DRAWER & CHIP WARMERS
F-41015 (03-14)
6
OPERATION
CONTROLS
The Warmer and its
parts are hot. Be very careful when 
operating, cleaning, or servicing the 
warmer. 
 
The warmer Control Panel contains an 
operating indicator light and a full range 
thermostat. (Fig.2) 
 
THERMOSTAT DIAL: 
The thermostat also acts as the On/Off 
switch to the warmer system. Turning 
the thermostat counter clock-wise until it 
stops will turn the warmer off. 
 
POWER LIGHT: 
The power light turns on and off as the 
heating elements cycle. 
 
POWER LIGHT
 
THERMOSTAT DIAL (Fig. 2) THERMOMETER  
It is recommended that prior to placing the warmer into operation that it be pre-
heated at the highest temperature setting for a period of 30 to 45 minutes 
. 
OPERATING INSTRUCTIONS
The Warmer and its
parts are hot. Be very careful when 
operating, cleaning, or servicing the 
warmer. 
 
Once the warmer has been connected 
to the appropriate power source, the 
warmer is ready for operation. 
 
The warmers have one, two, three, or 
four drawers depending on the model 
purchased. Each drawer has a 
separate thermostat dial and 
thermometer. 
 
 
 
Begin by turning the thermostat dial to 
the number 5. This will cause the 
heating element to start heating. When 
this occurs, the red operating indicator 
light will illuminate. This red light will 
stay on as long as the heating element 
is engaged. Once the predetermined 
temperature is achieved, the heating 
element will begin to cycle. During this 
period, the red operating indicator light 
will turn on and off as the heating 
elements cycle. 
 
The thermometer will begin to move and 
indicate the interior temperature of the 
drawer. (Fig. 3)