American Electric Lighting a division of Acuity Lighting Group, Inc. Conyers, GA

DRAWING NO. B60976 REV H

(BACK)

©2003 ACUITY LIGHTING GROUP, INC.

PART NUMBER 057-70-60976

B E A M P A T T E R N C H A R T

REFLT FINISH

DIFFUSED

REPORT NO.

P4958

P4956

P4957

BEAM SPREAD

6 X 5

6 X 6

7 X 6

SCKT POSITION

2

HPS

HPS

Open bezel by loosening the 1/4"

closer screws located at top of

flood. Loosen the 8 lens clip

screws and rotate clips.

Remove old lens parts and install

new lens. Rotate lens clips

and tighten lens clip screws.

LENS REPLACEMENT

HPS/MH WIDE BEAM

HPS NARROW BEAM

1

6 X 5

P4943

SEMI SPECULAR

LAMP

POSITION 1

POSITION 2

LENS CLIP SCREW

LENS CLIP

HPS

1

DIFFUSED

DIFFUSED

MH

2