NaceCare Solutions DM1800 User Manual

Page 18

Advertising
background image

Page -18-

N.A.C.E. Operator's Manual - DM1400 & DM1800

The UTV14 & UTV18 upright vacuums have 3 brush
performance indicator lights (see figure 25). They are
GREEN, YELLOW and RED. They work in the following
manner:

Normal Operation:

• The GREEN light is on when the brush drive motor is

on and the brush height setting is correct for the
carpet.

NOTE: It is normal for the red or yellow light to inter-
mittently turn on and off as high or low surfaces are
encountered.

Brush Height Too High:

• The YELLOW light will continue to stay on when the

brush height is too high for the carpet. Lower the
brush height setting.

Brush Height Too Low or Brush Has Jammed:

• The RED light will continue to stay on when the brush

height setting is too low for the carpet. Raise the
brush height setting. The RED light will come on if the
brush is jammed.

• If the RED light is on continuously for 10 seconds, the

electronic safety stop will protect the brush motor by
turning it off.

• To reset the brush drive motor, put the operating

handle in the upright position. Turn the ON/OFF
switch to the off position. Restart the machine.

• If the brush height was too low, raise the brush height

setting.

• If the brush was jammed, unplug the vacuum and clear

the brush.

BRUSH PERFORMANCE INDICATOR LIGHTS