Warnings, Important – NaceCare Solutions HZD750 User Manual

Page 3

Advertising
background image

3

Transport Chassis

The HZD 750 W/D machine is supported by a 4-wheeled stainless steel chassis. This
will carry the full weight of the machine and recovered debris. The front of the chassis
has a horizontal bar with two punched holes in it. This is to allow wide area wet or dry
cleaning kits to be fitted to the machine.

Accessories

This machine can be used with of all standard 1 1/2" and 2" Numatic accessories. It is
NOT recommended to use any of the 1 1/4" accessories as this substantially reduces
the airflow performance of the machine.

WARNINGS

If used for any potentially hazardous or health endangering material recovery, do not
use the machine unless the full filtration system is fitted. Failure to fit the complete
system may cause premature clogging of the HEPA filter cartridge and may also
endanger health.

Do not use the machine in corrosive or flammable environments.

Do not use this machine for the collection of explosive dusts.

When operating the machine in contaminated environment, always use protective
respiratory equipment and suitable approved personal protective clothing.

IMPORTANT

This machine may be equipped to handle hazardous dusts. This is only possible if fitted
with a HEPA filter module. Always take caution when emptying the machine as the dust
found in the container may be hazardous to your health.

If the machine will not run, check that the it is switched on and that power is available. If
the machine stops in use and restarts after a time, the high temperature cut-off device
may be activated. This may be indicative of blocked main filters, a blocked HEPA filter
or blocked hoses.

Servicing

Any servicing required should be carried out by qualified personnel.
Do not attempt to clean the microfilter cartridge. If it becomes excessively clogged, fit a
new unit. Take care when fitting the new cartridge not to handle or rupture the paper
element as this will affect the filtration efficiency of the machine. Care should also be
used in disposing of the old cartridge.

Always use genuine Numatic parts for any repairs required.

1205 Britannia Road E., Ontario, Canada L4W 1C7

Tel: (905) 795-0122

Fax: (905) 795-0038

U.S. Toll Free Tel: 1-800-387-3210

Toll Free Fax: 1-800-709-2896

Advertising