Small repairs - do it yourself – NaceCare Solutions K1120T User Manual

Page 19

Advertising
background image

19

The pressure gauge shows a 10% higher pressure than the working pressure.

You only get a weak flow of water or no water at all!

Small repairs - Do it yourself!

Small repairs - Do it yourself!

Small repairs - Do it yourself!

Small repairs - Do it yourself!

Small repairs - Do it yourself!

The injector may
be dirty and you
should first
remove
the hose!

Then straighten a
paper clip ...

... release feed
line and injector
with an open-
ended
spanner ...,

... and pull out
the injector!

Clean the injector
thoroughly from both
sides ...

and check that it

is clean.

Reconnect the
hose ...

and you are
ready to continue
your work!

Now turn on the water and
you should get a powerful
stream of water

Reconnect
injector and
feed line.

But if you only
get a weak flow

Advertising