NaceCare Solutions RM1800H User Manual

Page 6

Advertising
background image

Working process

A. Applying the chemical solution

B. Manual brushing (optional)

C. High pressure rinsing

D. Squeegee mirrors and flat surfaces

E. Vacuuming

F. Blow dry fixtures (optional)

STEP A – APPLYING CHEMICAL SOLUTION

1.

Set up the machine just outside the door of the area to be cleaned.

2.

Open the chemical input valve on the control panel.

3.

Switch the solution pump on. (Located on the upper control panel).

4.

Unroll the pressure line from the holder

5.

Adjust the spray gun to inject chemical by pulling the nozzle away from the trigger and

rotate to a fan pattern. In this position the spray gun is able to apply the water and

detergent under low pressure.

6. Apply the solution on the surfaces to be cleaned, starting at the nearest fixture and

working in a circular pattern. (Only apply the solution onto surfaces that will not be

damaged water)

7. Proceed from top to bottom and cover all surfaces that need cleaning.

8. Applying the chemical should take 3 to 5 seconds for urinals, 6 to 8 seconds for toilets

and 2 to 3 seconds for sinks. There is no need to over apply the chemical unless the

situation calls for it.

9. Now that you have worked your way back to the door and the machine, turn off the

chemical valve and rinse the chemical from the line onto the floor, again under low

pressure. (Do not inject chemical under high pressure at any time).

STEP B – MANUAL BRUSHING

This highly effective step is an option when time permits or when you encounter heavily

soiled floors.

When you are finished using the brush leave it by the door as you are going to high

pressure rinse it.

Advertising