MAINTENANCE PROCEDURES

ADJUSTMENT OF SIDE BRUSH

Figure 27
The regulation of the brush pressure on the floor can be made by adjusting the screw

behind the brush arm itself:

1. Loosen the lock nut.
2. Rotate the register screw counter clockwise until the bristles rest on the floor by about

2 cm.


SIDE BRUSH REPLACEMENT

Figure 28

1. Unscrew the brush fixing knob. Remove the brush paying attention not to lose the

washer and the knob .

2. Grease the shaft

3. Insert the new brush by putting the key into its place. Reassemble the washer and

the knob.

ADJUSTMENT OF CENTRAL BROOM

Figure 29

To adjust loosen the knob “a” and position the lever “b” in the following eyelets “c”.

Make the same adjustment on the opposite side.
During adjustment follow the broom alignment.


CENTRAL BROOM REPLACEMENT

Figure 30

1. Unscrew and remove all the knobs shown in the picture, and take out the brush

support group.

2. Remove the worn broom and insert the new broom. ATTENTION: keep the same

sense of direction of the bristles.

3. Reassemble the support group and the knobs in reverse order.