Troubleshooting, Cannot access the web user interface, Virtual loadmaster for microsoft hyper-v – KEMP Hyper-V 2012 User Manual

Page 16: 3 troubleshooting, 1 cannot access the web user interface

Advertising
background image

Copyright © 2002 - 2014 KEMP Technologies, Inc. All Rights Reserved. Page 16 / 20

Virtual LoadMaster for Microsoft Hyper-V

Installation Guide

3 Troubleshooting

3.1

Cannot access the Web User Interface

If a connection to the WUI cannot be established, network settings can be configured via the
console view.

1. Login into the VLM via the console using the settings:

lb100 login: bal
Password: 1fourall

Figure 3-1: Enter IP address

2. Enter the IP address of the eth0 interface, the network-facing interface of the LoadMaster,

in the input field within the Network Side Interface Address field and press Enter on the
keyboard.

Figure 3-2: Enter default gateway address

3. Enter the IP address of the Default Gateway.