3

6 Setting up the platform

shaker

(model SI30H only)

During transit, the platform is stored vertically at
the rear of the incubator chamber. It can remain
in this position whilst the rotisserie is in use. To
use the platform shaker for ‘sandwich box’
hybridisations, the following procedure should be
adopted:

6.1 Open the incubator door to its fullest extent,

Lift the rotisserie vertically and
store in a safe place.

6.2 Lift the platform by its handle (A on figure 4)

from its storage position, slide
it forward and locate it on the rocking
mechanism by placing the side pegs
of the platform into the retainers (D) on the
side walls of the incubator chamber.

This action seats the nylon blocks (C) on the
underside of the platform on to
the pegs (E) protruding from the rocker
mechanism at the rear of the incubator.

6.3 Place the box in which the hybridisation is

being performed on to the shaker platform
and close the incubator door.

6.4 Ensure that the desired temperature has

been set (see section 3.0).

6.5 Turn the rotisserie / shaker ON by pressing

the on / off button (1). The red indicator
light (3) above the speed selector dial (2) will
illuminate.

6.6 Rotate the rotisserie / shaker speed selector

dial (2) clockwise, until the desired
shaker speed is reached. Allowable values
are 5 – 70 strokes per minute.

The shaker platform will now oscillate at the
set speed.

6.7 When hybridisation is complete turn the

rotisserie / shaker OFF by pressing the on / off
button (1). The red indicator will go out (3).

7 Spares & accessories

The following spare parts are available for model
SI19 microtitre plate incubator.

Cat. No.

Description

DSI20053 Shelf, stainless steel
DSI20055 Drip tray, stainless steel

The following range of hybridisaion bottles and
rotisseries are available as optional extras for use
with model SI30H incubator / shaker.

Cat. No.

Description

SI20H/1 Rotisserie for 7 x 40mm diameter bottles
SI20H/2 Rotisserie for 2 x 75mm diameter bottles
SI20H/3 Hybridisation bottle 260 x 40mm
SI20H/4 Hybridisation bottle 260 x 75mm
SI20H/5 Hybridisation bottle 170 x 40mm
SI20H/7 Rotisserie for 24 x 50ml tubes

8 Electrical Installation

THIS INSTRUMENT MUST BE EARTHED

Before connection please read and
understand these instructions and ensure
that the line supply corresponds to that
shown on the rating plate.

Power consumption is:

Model

Power

Frequency

Fuses

SI19 280W 50Hz F3.15AL
SI30H 340W 50Hz

F3.15AL

The instruments are fitted with an IEC socket at
the rear of the instrument for connection of the
mains lead. The IEC socket contains a pull out
draw containing the fuses and a mains on/off
switch - see figure 2.