Technical specifications – APTech Series AK M60 User Manual

Page 5

Advertising
background image

AK M60 Manual

P/N 00-15000012 Rev 1

Page 5 of 13

3. TECHNICAL SPECIFICATIONS

3.1.

AK M60 Specifications

3.1.1. Physical

Dimensions are approximately 6-1/2 inch wide by 6-1/8 inch high by 8-1/2 inch deep

Weight is approximately 5 lbs.

Recommended to be panel mounted in 1-27/64 (1.42) inch diameter hole

3.1.2. Pressure and Flow

3500 psig maximum inlet pressure (can be limited by inlet gauge range)

250, 150, and 100 psig nominal outlet pressure options (specified when ordered)

75 slm nitrogen maximum flow at 200 psig minimum inlet pressure (higher flow rates may be

obtainable depending on inlet pressure and system components)

3.2.

AK M60 Facility Requirements

The following is needed to install the AK M60 manifold at the users facility.

1/4 inch NPT adapters

Secure mounting of the AK M60 to prevent loosening of fittings during operation of the knob

The recommended method of mounting the AK M60 manifold is with the panel mount feature. The panel
mount feature requires a 1-27/64 (1.42) inch diameter hole in a .30 inch maximum thickness panel. The
rear bonnet of the regulator is placed through the panel and secured in place with a panel nut as shown in
Figure 2. Alternately, it is possible to design a custom bracket that could secure the AK M60 manifold to
a fixed object.

The following is recommended for proper operation of the equipment:

Check valve for installation between each supply cylinder and each AK M60 inlet port

Manual valve for installation between cylinder and check valve

Appropriate purge and vent system for hazardous gases

Relief valve for installation on outlet delivery line

Advertising