4. INSTALLATION

This section describes how to install the equipment at a user facility.

4.1. General

Use Teflon® pipe thread tape on NPT connections. When mating a 316 stainless steel pipe fitting to a 316
stainless steel AK M60 body, it is recommended that Teflon tape be applied to the first NPT thread to
prevent galling upon assembly. For brass fittings, do not apply thread tape to the first NPT thread to
reduce the chance of introducing pieces of thread tape into the system. Use care not to apply Teflon tape
such that loose tape will come free and enter the flow path.

AP Tech recommends the use of Teflon tape for NPT connections to reduce the chance of galling 316
stainless steel threads, to maintain oxygen compatibility, and to maintain system cleanliness. Other types
of sealants can be used, but may not provide the same results.

Do not drop or jar the switchover manifold because damage to internal parts and pressure gauges may
result.

Inspect the manifold after unpacking and before installation. If any damage is observed, contact factory
for repair.

4.2.

AK M60 Installation

Select a location for the manifold that is sheltered from the environment and away from sources of heat or
sparks. The area should be protected from vehicles and moving mechanical equipment. The area must be
accessible for ease of cylinder replacement.

A panel or bracket with a 1-27/64 inch hole is recommended to secure the AK M60 crossover manifold
and prevent movement during operation. Refer to Figure 2 for mounting location.

Figure 2. AK M60 Crossover Manifold Panel Mounting Detail

Advertising