Removal of dynamic seal – Goulds Pumps ANSI FAMILY IOM (ATEX Compliant) - IOM User Manual

Page 62

Advertising
background image

3.

Remove stuffing box cover (184). (Fig. 55).

4.

Remove shaft sleeve (126) (Fig. 56).

5.

Remove packing (106) and lantern ring (105) from
stuffing box cover (184) (Fig. 57). No lantern ring
is provided with self-lubricating graphite packing.

REMOVAL OF DYNAMIC SEAL

- 3196, CV 3196,

LF 3196

1.

Remove stud nuts (370H).

2.

Remove dynamic seal assembly (Fig. 58).

3.

Remove socket head cap screws (265) (Fig. 59).

4.

Remove stuffing box cover (184) and gasket
(264).

5.

Remove repeller (262) from backplate (444).

60

ANSIFAM IOM - 5/08

Fig. 55

Fig. 57

Fig. 56

126

Fig. 58

Fig. 59

Advertising
This manual is related to the following products: