Bearing Frame

1.

Visually inspect bearing frame (228) and frame
foot (241) for cracks. Check frame inside surfaces
for rust, scale or debris. Remove all loose and
foreign material (Figs. 96, 97).

2.

Make sure all lubrication passages are clear.

3.

If frame has been exposed to pumpage, inspect
for corrosion or pitting.

4.

Inspect inboard bearing bore according to
Table 8.

C-Face Adapter

For C-Face adapter inspections, See Appendix V.

Dynamic Seal Repeller

(3196, CV 3196, LF 3196 only)

1.

Inspect dynamic seal repeller (262) vanes for
damage. Replace if grooved deeper than 1/16 in.
(1.6 mm) or if worn evenly more than 1/32 in.
(0.8 mm) (Fig. 98).

2.

Inspect sleeve surface for grooves, pitting or other
damage. Replace if damaged.

Seal Chamber/Stuffing Box Cover and
Dynamic Seal Backplate

1.

Make sure seal chamber/stuffing box cover (184)
and dynamic seal backplate (444) gasket
surfaces, and mounting surfaces, are clean
(Figs. 99 - 107).

2.

Replace if there is any pitting or wear greater than
1/8 in. (3.2 mm) deep.

3.

Inspect machined surfaces and mating faces
noted on Figures 99-107, and clean as
necessary.

70

ANSIFAM IOM - 5/08

Fig. 97

Fig. 98

Fig. 99

BigBore™ Chamber

Fig. 96

Fig. 100

Stuffing Box Cover

241

262

Advertising