DISMANTLING (PUMP WITH MECHANICAL SEALS ON SHAFT)

!

WARNING

Prior to working on pump the power source
should be disconnected with lockout provisions
so power cannot be re-energized
to the motor. Close isolating suction and
discharge valves. Failure to follow these
instructions could result in properly damage,
sever personal injury, or death. (See exploded
view on page 64.)

1.

Drain the pump by opening vent plug (A, Fig. 28)
and remove drain plugs (B and C) on the suction
and discharge nozzles.

2.

Remove all casing main joint cap screws
(2-904-1) and dowels (2-916-1). Remove external
tubing (0-952-0).

3.

Insert a screwdriver or pry bar into the slots
between the upper and lower casing halves, and
separate the halves, lifting off the upper casing
half.

NOTE: Some casings have jacking screws.

42

3408 IOM 03/99

Fig. 27

Fig. 28

A- VENT PLUG

...........

è

B- DRAIN PLUG

......

è

C- DRAIN PLUG

..........

è

Dowel Pin Location

at Parting Line