29. Reinstall all main joint bolts, following tightening

sequence illustrated in Fig. 58, page 55. (The
number of casing bolts varies with the size of the
pump.) Torque bolts 140 ft-lb minimum for 5/8"-11
hex head cap screws (Grade 5) and 350 ft-lb
minimum for 7/8"-9 Ferry Cap Countr-bor screws
(Grade 8)

NOTE: Torquing bolts to proper values in proper
sequence is essential in obtaining proper gasket
compression so no leakage can occur at main
joint.

30. Rotate shaft making sure it spins free. If the motor or

line shafting has been removed it will now be possible
to reinstall.

Complete Pump Removal

Should it be necessary to remove a complete pump, it
will be necessary to remove the line shafting or motor,
disconnect the pedestal from its anchor bolts, disconnect
and remove, if necessary, sections of the suction and
discharge piping, and turn the entire pedestal horizontal
enabling complete pump removal from horizontal position.

Fig. 58

6