Maintenance of bearings – Goulds Pumps 3910 11th ed. - IOM User Manual

Page 28

Advertising
background image

INSPECTION INTERVALS

Inspection intervals should be shortened appropriately
if the pumpage is abrasive and/or corrosive,

!

or if the enviornment is classified as potentially
explosive.

MAINTENANCE OF BEARINGS

!

Do not insulate bearing housings as this can result
in excess heat generation, sparks, and premature
failure.

!

Service temperature in an ATEX classified environ-
ment is limited to the area classification specified on
the ATEX tag affixed to the pump (reference
Table 1
in the
Safety section for ATEX classifications).

GREASE LUBRICATED BEARINGS

Grease lubricated bearings are pre-lubricated at the
factory.
Regrease bearings every 2000 operating hours or
3 months, whichever occurs first.

Regrease Procedure

NOTE: When regreasing there is danger of impurities
entering the bearing housing. The grease container,
the greasing device, and fittings must be clean.

1.

Wipe dirt from both grease fittings (Fig. 11).

2.

Remove two grease relief plugs from side of frame
opposite grease fittings.

3.

Fill both grease cavities through grease fittings with
recommended grease until fresh grease comes out of
the relief holes. Reinstall grease relief plugs until
immediately prior to starting pump.

NOTE: The bearing temperature usually rises after
regreasing due to an excess supply of grease. Temper-
atures will return to normal after pump has run and
purged the excess from the bearings, usually two to
four hours. Grease relief plugs should be removed
during this period, and replaced when temperature
has stabilized.

For most operating conditions a lithium based mineral oil
grease of NLGI consistency number 2 is recommended.
This grease is acceptable for bearing temperatures of -15°C
to 110°C (5°F ro 230°F).

Bearing temperatures are generally about 20°F (18°C)
higher than bearing housing outer surface temperature.

Some acceptable greases are:

NLGI Consistency

2

Exxon

Unirex N2

Mobil

Mobilux EP2

Sunoco

Multipurpose EP

SKF

LGMT 2

$

!

CAUTION

Never mix greases of different consistency (NLGI 1 or
3 with NLGI 2) or different thickener. For example,
never mix a lithium base grease with a polyurea base
grease.

NOTE: If it is necessary to change grease type or
consistency, the pump must be disassembled and the
old grease removed from the bearings.

PURE OIL MIST LUBRICATED
BEARINGS (OPTIONAL)

s

!

WARNING

Pumps are shipped without oil. Oil mist lubricated
bearings must be lubricated at the job site.

1.

Follow oil mist system supplier’s instructions.

2.

Connect oil mist supply lines to upper and center
tapped connection.

28

3910-1

1th IOM 5/08

Fig. 11

Advertising