Table 6 minimum running clearances, Seal chamber cover (184) – Goulds Pumps 3910 11th ed. - IOM User Manual

Page 39

Advertising
background image

Table 6

Minimum Running Clearances

Diameter of

Impeller

Wear Ring

Minimum

Diametral
Clearance

mm

in.

mm

in.

<50

<2.000

0.25

0.010

To to 64.99

2.000 to 2.4999

0.28

0.011

65 to 79.99

2.500 to 2.999

0.30

0.012

80 to 89.99

3.000 to 3.499

0.33

0.013

90 to 99.99

3.500 to 3.999

0.35

0.014

100 to 114.99

4.000 to 4.499

0.38

0.015

115 to 124.99

4.500 to 4.999

0.40

0.016

125 to 149.99

5.000 to 5.999

0.43

0.017

150 to 174.99

6.000 to 6.999

0.45

0.018

175 to 199.99

7.000 to 7.999

0.48

0.019

200 to 224.99

8.000 to 8.999

0.50

0.020

225 to 249.99

9.000 to 9.999

0.53

0.021

250 to 274.99

10.000 to 10.999

0.55

0.022

275 to 299.99

10.000 to 11.999

0.58

0.023

300 to 324.99

12.000 to 12.999

0.60

0.024

SEAL CHAMBER COVER (184)

Seal chamber cover is available in two versions: one
(optional) has a cooling chamber and water jacket cover
(490) and the other (standard) does not. The (optional)
cooled version is used when elevated pumpage
temperatures are present.

1. Ensure all gasket/O-ring sealing surfaces are clean and

have no damage that would hinder or prevent sealing
(Fig. 28).

2. Ensure all cooling (where applicable), flush and drain

passages are clear.

3. Inspect other surfaces for damage. Replace if worn,

damaged or corroded more than 3.2 mm (

1

8

in.) deep.

4. Measure inside diameter of seal chamber cover

bushing (125). If the diametral clearance between it
and the impeller hub (101) exceeds 1.20 mm (.047 in.),
one or both parts should be replaced. Refer to
Renewal of Wear Parts for replacement instructions
for seal chamber cover bushing.

3910-1

1th IOM 5/08

39

Fig. 26

Fig. 27

Fig. 28

6

Advertising