Goulds Pumps 3910 11th ed. - IOM User Manual

Page 9

Advertising
background image

S-5

General Precautions

WARNING



Before beginning any alignment procedure, make sure driver power is locked out.

Failure to lock out driver power will result in serious physical injury.

CAUTION



Piping:
Never draw piping into place by forcing at the flanged connections of the pump.

This may impose dangerous strains on the unit and cause misalignment between

pump and driver. Pipe strain will adversely effect the operation of the pump

resulting in physical injury and damage to the equipment.

WARNING

Flanged Connections:
Use only fasteners of the proper size and material.

WARNING

Replace all corroded fasteners.

WARNING

Ensure all fasteners are properly tightened and there are no missing fasteners.

WARNING



Startup and Operation:
When installing in a potentially explosive environment, please ensure that the

motor is properly certified.

WARNING



Operating pump in reverse rotation may result in contact of metal parts, heat

generation, and breach of containment.

WARNING



Lock out driver power to prevent accidental start-up and physical injury.

WARNING



The impeller clearance setting procedure must be followed. Improperly setting

the clearance or not following any of the proper procedures can result in sparks,

unexpected heat generation and equipment damage.

WARNING



If using a cartridge mechanical seal, the centering clips must be installed and set

screws loosened prior to setting impeller clearance. Failure to do so could result

in sparks, heat generation, and mechanical seal damage.

WARNING



The coupling used in an ATEX classified environment must be properly certified

and must be constructed from a non-sparking material.

WARNING

Never operate a pump without coupling guard properly installed. Personal injury

will occur if pump is run without coupling guard.

WARNING



Make sure to properly lubricate the bearings. Failure to do so may result in excess

heat generation, sparks, and / or premature failure.

CAUTION



The mechanical seal used in an ATEX classified environment must be properly

certified. Prior to start up, ensure all points of potential leakage of process fluid to

the work environment are closed.

CAUTION



Never operate the pump without liquid supplied to mechanical seal. Running a

mechanical seal dry, even for a few seconds, can cause seal damage and must be

avoided. Physical injury can occur if mechanical seal fails.

WARNING

Never attempt to replace packing until the driver is properly locked out and the

coupling spacer is removed.

WARNING



Dynamic seals are not allowed in an ATEX classified environment.

WARNING



DO NOT operate pump below minimum rated flows or with suction and/or

discharge valve closed. These conditions may create an explosive hazard due to

vaporization of pumpage and can quickly lead to pump failure and physical injury.

Advertising