WARNING: Always wear ear protection where the sound level exceeds 85dB(A)
and limit the time of exposure if necessary. If sound levels are uncomfortable, even
with ear protection, stop using the tool immediately and check the ear protection is
correctly fitted and provides the correct level of sound attenuation for the level of
sound produced by your tool.
WARNING: User exposure to tool vibration can result in loss of sense of touch,
numbness, tingling and reduced ability to grip. Long term exposure can lead to a
chronic condition. If necessary, limit the length of time exposed to vibration and
use anti-vibration gloves. Do not operate the tool with hands below a normal
comfortable temperature, as vibration will have a greater effect. Use the figures
provided in the specification relating to vibration to calculate the duration and
frequency of operating the tool.
Sound and vibration levels in the specification are determined according to
EN60745 or similar international standards. The figures represent normal use for
the tool in normal working conditions. A poorly maintained, incorrectly assembled,
or misused tool, may produce increased levels of noise and vibration. www.osha.
europa.eu provides information on sound and vibration levels in the workplace that
may be useful to domestic users who use tools for long periods of time.
Carefully read and understand this manual and any label attached to the tool
before use. Keep these instructions with the product for future reference. Ensure
all persons who use this product are fully acquainted with this manual.
Even when used as prescribed it is not possible to eliminate all residual risk
factors. Use with caution. If you are at all unsure of the correct and safe manner in
which to use this tool, do not attempt to use it.

General Power Tool Safety

Warnings

WARNING Read all safety warnings and all instructions. Failure to follow the

warnings and instructions may result in electric shock, fire and/or serious injury.
WARNING: This appliance is not intended for use by persons (including children)
with reduced, physical or mental capabilities or lack of experience or knowledge
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children must be supervised to
ensure that they do not play with the appliance.
Save all warnings and instructions for future reference.
The term 'power tool' in the warnings refers to your mains-operated (corded)

power tool or battery-operated (cordless) power tool.

Work Area Safety

a)

Keep work area clean and well lit. Cluttered or dark areas invite accidents

b)

Do not operate power tools in explosive atmospheres, such as in the

presence of flammable liquids, gases or dust. Power tools create sparks

which may ignite the dust or fumes

c)

Keep children and bystanders away while operating a power tool.

Distractions can cause you to lose control

Electrical Safety

a)

Power tool plugs must match the outlet. Never modify the plug in any

way. Unmodified plugs and matching outlets will reduce risk of electric

shock

b)

Avoid body contact with earthed or grounded surfaces, such as pipes,

radiators, ranges and refrigerators. There is an increased risk of electric

shock if your body is earthed or grounded

c)

Do not expose power tools to rain or wet conditions. Water entering a

power tool will increase the risk of electric shock

d)

Do not abuse the cord. Never use the cord for carrying, pulling or

unplugging the power tool. Keep cord away from heat, oil, sharp edges

or moving parts. Damaged or entangled cords increase the risk of electric

shock

e)

When operating a power tool outdoors, use an extension cord suitable

for outdoor use. Use of a cord suitable for outdoor use reduces the risk of

electric shock

f)

If operating a power tool in a damp location is unavoidable, use a

residual current device (RCD) protected supply. Use of an RCD reduces

the risk of electric shock

NOTE:

The term ‘residual current device (RCD)’ may be replaced by the

term ‘ground fault circuit interrupter (GFCI)’ or ‘earth leakage circuit breaker
(ELCB)’.

Description of Symbols

The rating plate on your tool may show symbols. These represent important
information about the product or instructions on its use.

Wear hearing protection
Wear eye protection
Wear breathing protection
Wear head protection

Wear hand protection

Read instruction Manual

Class I construction (Protective earth)


Conforms to relevant legislation and safety standards

Environmental Protection

Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice

Specification


Voltage ....................................................... 230V~
Frequency .................................................. 50Hz
Power. ........................................................ 200W
Wheel size .................................................. 150 x 20 x

12.7mm
Supplied wheel grades ............................... medium & fine
No load speed ............................................ 2950min-1
Uncertainty ................................................. 1.5m/s²
Sound pressure .......................................... 63dB(A)
Sound power .............................................. 76dB(A)
Uncertainty. ................................................ 3dB(A)
Protection class .......................................... Class 1
Ingress protection rating ............................ IP20
Insulation ................................................... Class B
Duty Cycle .................................................. S2, short-time

duty, 30min on/30min off

The sound intensity level for the operator may exceed 85dB(A) and

sound protection measures are necessary.

As part of our ongoing product development, specifications of

Silverline products may alter without notice.

263524_Z1MANPRO1.indd 4