Sv start velocity<value – RMS Technologies R101 DRIVER/INDEXER User Manual
Page 36
                                    Advertising
                                    
                                        
                                    
                                
                                
RMS Technologies
Page 36
Version 1.31
R101 Single Axis Driver/Indexer Manual
10/1/2007
SV
Start Velocity<value>
 
 
Command or Query 250 to 15,000
 
Reads or sets the velocity used for the first step in a position move. Value based on 
motor performance. 
 
 
Command Example 
 
#ASV500<cr><lf> Sets Start Velocity to 500 PPS.
Default value is 1,000