ABOUT Dual Head PERISTALTIC PUMPS

The Dual Head Peristaltic Ink pump can be used to supply and draw back ink/fluid to one print deck, supply
the same ink/fluid to two different decks, or supply different ink/fluids to two different decks.

The Dual Head Peristaltic pump includes a hollow shaft pump motor (with female adapters and cord), two
pump heads (large or small) with male adapters, remote control unit, mounting frame and power cord. The
remote control unit is connected to the pump motor with a motor cord. (Left in Figure C, page 1) The power
cord is plugged into the remote control unit (Right in Figure C, page 1) and supplies 110 or 240VAC power.
The remote control unit automatically senses the voltage and is ready to operate. Once the pump motor cord
is plugged into the underside of the remote control unit and pump heads are properly installed, the system is
ready to pump.

The Remote Control unit is not splash-resistant, and therefore cannot be mounted in areas where fluid spills
can damage or disable the unit. The unit is designed to be mounted on a vertical surface with the switch and
cord receptacle facing down.

The pump and motor unit is splash-resistant under normal usage. DO NOT immerse the pump in fluids.
Contact a Graymills representative about mounting options for the pump and accessories, including stands,
filters, mixers and pails.


The Dual Head pump is offered in two models: PPS and PPL. The pump motor will accept either pump
head size, but the remote control unit is factory set for one specific model. Do not drive PPS heads
with a PPL control unit, or drive a PPL head with a PPS control unit.

.

For complete information about roller and hose, see the OMI #795-09456.

OPERATING PUMP

Turning On
See Figure C, page 1, showing power switch location on Remote Control Unit base.

Changing Pump Direction
Specifics of switch operation for speed and direction control are in OMI #795-09456.

Like all peristaltic pumps, stopping the Dual Head will not allow lines above the pump to gravity drain
because the rollers in the peristaltic pump head keep the hose partially closed after the motor is
stopped. It may be necessary to remove or rearrange hoses, particularly if both lines are going to a
single deck, in order for the deck to drain.

Fusing for the PPL-DV-DH and PPS-DV-DH Model
For 115 and 230VAC pump operation, use two (2) fuses, Part #780-91518 (5 x20mm, 5.0 Amp,
250VAC, Type FST, Slow Blow)

PUMP HEAD Removal/Installation
Installing or Removing a complete Pump Head, Male Adapter and Hose assembly with another of same.

For both PPS and PPL Dual Head Peristaltics, the following:

Stop pump and disconnect power supply.

Press Release Lever and remove current Pump Head Assembly from motor.

Ensure one large key is in the short shaft keyway of the new Pump Head Assembly.

Align this key with keyway of hollow shaft in motor and press Pump Head assembly into motor.

If necessary rotate Pump Head slightly until key and keyway align.

Press Release Lever and continue pressing Pump Head assembly into motor to close the gap between

two mating Adapters.

Rotate and Lock Pump Heads as desired.

Remove pressure from Release Lever to allow spring pin to engage with Male Adapter. Rotate and pull on

Pump Head to ensure it is properly secured and will not pull off.

Pump Head Assembly is now ready for operation.