Service – Graymills DDP .5' Pump User Manual

Page 14

Advertising
background image

14

Service

Ball or Duckbill Check Valves

NOTE: Use Fluid Section Repair Kit 784–90612 for
Hytrel Diaphragm pumps and 784–90613 for PTFE Dia-
phragm pumps. General purpose grease and adhesive are
supplied in the kits.

1.

Relieve the pressure. See Pres-
sure Relief Procedure
on page 10.

2.

Remove the top and bottom manifolds (102, 103).

3.

Remove all parts shown with a dagger ( ).

4.

Clean all parts, and replace worn or damaged parts.

5.

Reassemble the pump.

NOTE: Torque the manifold nuts (109) or bolts (105)
to 80 to 90 in-lb (9 to 10 N-m).

Inlet and Outlet for Pumps with Duckbill
Check Valves

Pumps with duckbill check valves are shipped with the
inlet manifold on bottom and the outlet manifold on the
top. To make the inlet manifold on the top and the outlet
manifold on the bottom, rotate each of the four duckbill
assemblies vertically 180 as shown below. This may be
necessary in applications where pump priming is problem-
atic.

202

201

139

Figure 7

103

202

202

201

301

139

201

301

202

201

139

109

109

Torque to 80 to 90 in-lb (9 to 10 N-m).

202

201

139

102

Split Manifold Pump

139

139

139

Advertising