26

1

3
4

2

01441C

01442

102

101

106

102

107

112

*401

118

402*

1

1

13/32 IN. EZY-OUT

01443

CUTAWAY VIEW OF DIAPHRAGM
ASSEMBLIES IN PUMP HOUSING

1

31

}

DETAIL OF BEARING REMOVAL USING EZY-OUT

*401

AIR SIDE

FLUID SIDE

301*

*108

*108

111

301*

403*

3

118

23

30

}

404*

Apply thread lubricant.

Grease shaft.

Do not over-torque.

Round side must face toward diaphragm.

Flat side faces ball.

Beveled end up.

Apply medium-strength (blue) Loctite

R

or

equivalent. Torque to 75 to 85 in-lb
(8.5 to 9.6 N-m) at 100 rpm maximum using a
1/2-in. socket wrench.

Torque to 50 to 60 in-lb (5.6 to 6.8 N-m).

6
7

8

9

104

202*

201*

202*

201*

106

23

}

*404

103

01440

101

111

1

10

Notches must
engage
tabs.

DETAIL OF CLAMPS AND COVERS

113

8

10

2

7

7

2

2

4

4

3

3

9

8

1

1

6

9

5

113