Performance Charts

Test Conditions:

Pump tested in water with inlet submerged.

0

20

40

60

80

100

120

0

5

10

15

20

25

30

35

40

(0.7, 7)

Fluid Pressure Curves

A at 120 psi (0.7 MPa, 7 bar) air pressure

B at 100 psi (0.7 MPa, 7 bar) air pressure

C at 70 psi (0.48 MPa, 4.8 bar) air pressure

D at 40 psi (0.28 MPa, 2.8 bar) air pressure

A

B

D

To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow
(gpm/lpm) and operating air pressure
(psi/MPa/bar):

1. Locate fluid flow rate along bottom of

chart.

2. Follow vertical line up to intersection

with selected fluid outlet pressure curve.

3. Follow left to scale to read fluid outlet

pressure.

FLUID OUTLET PRESSURE

––

psi (MPa, bar)

(0.55, 5.5)

(0.41, 4.1)

(0.28, 2.8)

(0.14, 1.4)

C

(0.84, 8.4)

FLUID FLOW--gpm (lpm)

(38)

(133)

(152)

(76)

(114)

(95)

(57)

(19)

0

10

20

30

40

50

60

0

5

10

15

20

25

30

35

40

FLUID FLOW--gpm (lpm)

AIR CONSUMPTION

––

scfm (cubic meters/min)

To find Pump Air Consumption (scfm or
m

#/min) at a specific fluid flow (gpm/lpm) and

air pressure (psi/MPa/bar):

1. Locate fluid flow rate along bottom of chart.

2. Read vertical line up to intersection with

selected air consumption curve.

3. Follow left to scale to read air consumption.

(38)

(133)

(1.68)

(152)

(76)

(114)

(1.40)

(1.12)

(0.84)

(0.56)

Air Consumption Curves

A at 120 psi (0.7 MPa, 7 bar) air pressure

B at 100 psi (0.7 MPa, 7 bar) air pressure

C at 70 psi (0.48 MPa, 4.8 bar) air pressure

D at 40 psi (0.28 MPa, 2.8 bar) air pressure

B

C

A

D

(0.28)

(95)

(57)

(19)

Advertising