UNPACKING

Remove your cleaner from its packaging and ensure that along

with Operations and Maintenance Instructions, you have been

supplied with a power cord.

SAFETY INSTRUCTIONS

Read this before using your product.
• Never operate unit without the safety ground (earth) from the

AC power cord intact.

• Do NOT operate this unit if the cord or plug is damaged.
• To avoid electric shock, do NOT touch the cord or socket

with wet hands.

• Unplug unit before filling. Do NOT fill with boiling cleaning

solution as damage to the unit may occur. Always fill the unit

above the “MIN” marker line before use.

• Always unplug the unit before emptying.

• Do NOT attempt to remove screws or panels on the unit as

there are no serviceable parts inside. Doing so will void

warranty.

• Do NOT fill the tank with abrasives or corrosive chemicals.
• Always turn off power when not in use.
• Do NOT operate the unit without cleaning solution in the

cleaning tank as damage may occur.

• The unit should not be left unattended when running.
• Do NOT clean items that are incompatible with your

cleaning solution or are delicate/fragile as damage may

occur.

UNIT SET UP

1 Place the unit on a stable and flat working surface.
2 Before connecting the power cord, add cleaning solution

to the tank, sufficient to completely immerse the items to be

cleaned.

3 Always fill the unit above the “MIN” marker line indicated

on the inside of the tank.

4 Replace cover. Connect the power cable and turn on the

power switch on the rear of the unit. Press the ON/OFF

button on the front panel to turn the cleaner ON.

5 The cleaning fluid needs to be de-gassed prior to cleaning

your parts.

Set the timer to 10 minutes (see ”Setting the

Timer”) and allow the ultrasonic cleaning function to run

without parts in the tank.

6 Place the items to be cleaned in tank or optional stainless

steel basket and replace cover. You are now ready to set the

timer and temperature to your desired cleaning process.

OPERATING INSTRUCTIONS

Setting the Timer

Press the s and t buttons to increase or decrease the

desired cleaning time. Once the timer is set, press “ON”

to start the ultrasonic cleaning function. The timer display

will count down the remaining time in minutes and seconds.

Once the timer reaches 00, the cleaning process will stop.

Timer adjustment can be made while the unit is in operation.
The unit will enter ‘standby’ mode 60 seconds after the

cleaning cycle has finished. To re-start the unit, press the

ON/OFF button.

Setting the Temperature

When power is connected, the temperature of the

cleaning solution in the tank is displayed in the “ACTUAL

TEMPERATURE” window.
Press the “HEATER TEMPERATURE” s button to increase, or

the t button to decrease the desired temperature.
While heating is occurring, the red “HEATING” light will

illuminate. The “ACTUAL TEMPERATURE” display shows the

current cleaning solution temperature. If cleaning solution

temperature is higher than the setting temperature, the

heating process stops automatically and the red indicator

light goes off. If cleaning solution temperature is lower

than the setting temperature, the heating process carries on

and the red indicator light remains on. For best results, the

temperature should be between 130° to 160°F (55° to 70° C).

Excessive heat or prolonged cleaning times can cause

damage to your items. If necessary, test clean your items at

a temperature lower than 130°F until you are sure they can

withstand the higher temperature

. If you need assistance

determining cleaning times for your specific application, please

call Customer Service at 888-472-6455.

Hot cleaning solution can cause scalding. Wear appropriate

personal protective equipment when operating the unit with

cleaning solution above 110°F. Take care not to splash cleaning

solution on yourself or bystanders when loading and unloading

the unit. If cleaning solution is splashed on you, follow the

instructions on the chemical manufacturer’s MSDS.

When finished using the ultrasonic cleaner:
• Ensure unit is in ‘standby’ mode by pressing the ON/OFF

button and checking that the displays turn off.

• Turn off the power switch on the rear of unit and disconnect

the unit from the electrical supply.

CLEANING THE UNIT

Before cleaning, unit must be unplugged.
Allow cleaning solution to cool. Drain unit and wipe the

stainless steel tank and housing with a clean dry cloth. DO

NOT wash the unit with cleaning solution.

STORAGE

The unit should be stored in a cool dry place.

795-92558 10-11 BTV OMI