CAUTION

The work area should be well ventilated.

Provide adequate lighting in the work area to permit
viewing of the cleaning process and of the floor area
around the machine. Be sure to allow adequate room
to bring work to and from the machine. Use flooring or
floor covering that does not become slippery when wet.
Provide sufficient clearance around the machine for
fluid changeovers and servicing.


INSTALLATION

UNPACKING

Check containers for any sign of external damage.
Carefully unpack cartons. If any damage is determined,
immediately notify carrier.

LOCATING THE MACHINE

The machine should be placed in a dry location free
from water mist or spray. The internal electronic
components can be damaged by high humidity or
water spray. When filling the machine and rinsing any
parts after ultrasonic cleaning avoid
water spray on the intake lovers, back
and underside of the ultrasonic
cleaning system.



M

AIN

P

OWER

There is one (1) main power switch that allows power
to the machine.

U

LTRASONICS

Ultrasonics provides scrubbing cavitation for precision
cleaning. This system features ultrasonic generators
and employs transducers immersed in the fluid. On the
control panel, there is one (1) switch that controls the
timer for the ultrasonics. Start, starts the timer cycle
and reset stops and resets the time on the timer. See
section on timer for explanation on how to set the
timer.

HEATER

There are four (4) 500-watt (120V) heaters attached to
the side of the ultrasonic tank. The temperature control
thermostat controls the temperature. See section on
digital thermostat on an explanation on how to set the
thermostat. The switch on the control panel turns on
the heater. Turning the switch to the right activates the
heater timer; turning to the left overrides the timer and
continuously activates the heater. See section on
heater timer

(Appendix A) for an explanation on how to

set the day timer.

P

UMP

There is one (1) switch on the control panel
that controls the pump and filtering of the
system. A valve by the filter housings will
control the flow. Too much flow when using

the ultrasonics as the flow will impede the
ultrasonic's capacity to clean

.

O

IL

S

KIMMER

There is one (1) switch on the control panel
that controls the oil skimmer

.


Ultrasonic Timer

Pump

Heater Timer

Oil Skimmer

Heater
(Temperature)
Controller

Main (Power) Switch

Heat On/Off

Ultrasonic On/Off