SAFETY WARNINGS

You will find various types of safety information on the following pages

and on the labels attached to Graymills equipment. The following

Safety Statements explain their meaning:

This is the safety alert symbol. It is used to alert you to potential

personal injury hazards. Obey all safety messages that follow

this symbol to avoid possible injury or death.

DANGER indicates a hazardous situation

which, if not avoided, will result in death or

serious injury.

WARNING indicates a hazardous situation

which, if not avoided, could result in death or

serious injury.
CAUTION, used with the safety alert symbol,

indicates a hazardous situation which, if not

avoided, could result in minor or moderate

injury.
CAUTION, used without the safety alert symbol,

is used to address practices not related to

personal injury.
The NOTE symbol means that failure to follow

these instructions could cause damage to the

equipment or cause it to operate improperly.

Reference Figures are located on Page 5.

Never work with equipment you feel may be unsafe. Contact

your Supervisor immediately if you feel a piece of equipment is

in an unsafe condition.

Never uSe a flammable or CombuStible fluid iN the

tempeSt. uSe oNly NoNflammable, NoN-CombuStible,

water-baSed, low foamiNg CleaNiNg CompouNdS iN

thiS maChiNe.
do Not CoNtamiNate CleaNiNg fluid with aNy

flammable or CombuStible material SuCh aS gaSoliNe,

alCohol, miNeral SpiritS, etC. draiN partS to be

CleaNed of aNy flammable material or CombuStible

material before plaCiNg iNSide CleaNiNg taNk. eveN

Small quaNtitieS CaN Create a daNgerouS fire

hazard.

always wear appropriate safety items such as gloves, apron, safety

glasses or goggles when loading, using or unloading or cleaning the

tempest.
follow all directions, warnings and Cautions that are in the material

Safety data Sheet (mSdS) for the cleaning detergent being used.
in an accident where any cleaning solutions are splashed on clothing

follow mSdS. remove wet clothing promptly and thoroughly wash

body areas that have been in contact with the solution. do Not permit

saturated clothing to remain in contact with skin. industrial cleaners can

cause irritation to some individuals.
Cleaning solutions may irritate skin and eyes. if splashed in eyes, flush

thoroughly with water. Consult material Safety data Sheet (mSdS) and

a physician.
• If you have any questions regarding the correct cleaning fluids

to use in this unit, call graymills at 773-248-6825 and ask for

Customer Service. we recommend our low foaming aquatene

™.

unit must be properly grounded to prevent electric shock hazard.

Connect only to three prong outlet. Should plug or cord become

cracked, frayed, damaged in any way, it should be repaired/replaced

immediately by a qualified electrician.
Never use an extension cord.
Since operator safety is at all times a priority, this unit is equipped

with a ground fault interrupter (gfi). Should plug or cord require

replacement, it should be wired by a licensed electrician to the gfi in

the control box.
all electrical connections should conform to national/local codes and

be made by qualified personnel.
before performing any maintenance on this unit, be sure to disconnect

electric power.
prior to changing cleaning fluid or servicing the tempest, make sure

that all moving parts have stopped and that heating element and

cleaning solution have cooled.
pump operation is controlled by depressing an air switch foot pedal.

for safety, if this must be replaced, use only the same air switch, not an

electrically operated one.
keep pump and motor clean and free of all contaminates. Never allow

any liquids to come into contact with motor or electrical systems as an

electric shock hazard could result.
thermostat and pressure parameters have been factory set and must

never be tampered with.

The Tempest 10, 10S and 20S Units are preset to operate up to

600 PSI. operating with pressure greater than 600 pSi can create a

hazardouS situation.

• Tempest is equipped with a pressure relief valve in the spray cabinet

(figure 6). when pressure is relieved, the valve automatically resets.

Should pressure inside spray delivery system reach an unsafe level,

relief valve will vent excess pressure back into cabinet. this valve

must be kept clean and free of all contaminants to insure its proper

functioning. activation of the pressure relief valve is not expected

during normal operation.

do Not start spray pump unless you have a firm grip on the nozzle. if

nozzle is dropped, stop pump immediately. an unrestrained hose and

nozzle could cause injury, damage to cabinet and parts in it, as well as

break the window, causing possible injury. restrain parts which might

be violently moved by high pressure spray.
Never aim spray directly at gloves or anything other than parts to be

cleaned.

Tempest is equipped with a safety interlock switch that prevents the

pump from operating unless the cabinet door is closed and secured

with door hasps. Never override safety interlock switch or operate this

unit if the safety interlock switch is not functional.
Never open cabinet door when spray pump is operating, or try to

override the safety switch. if switch fails, do Not use tempest until

replaced.
do Not overload unit. maximum capacity is 500 pounds.

be careful to avoid hot areas within the cleaning chamber when

opening unit.
parts will be heated during cleaning. wear appropriate clothing and

protection.
Never operate unit with a cleaning solution reservoir level below

minimum or activate heater when it is not immersed in liquid.

do Not operate unit without a filter bag.