6 operating the vm-24h, 1 controlling via rs-232, Operating the vm-24h – Kramer Electronics VM-24H User Manual

Page 14: Controlling via rs-232, Figure 4: crossed cable rs-232 connection, 6operating the vm-24h

Advertising
background image

VM-24H - Operating the VM-24H

11

6

Operating the VM-24H

This section describes how to:

Control the VM-24H via RS-232, see

Section

‎6.1

Operate the VM-24H, see

Section

‎6.2

Use the EDID button, see

Section

‎6.3

6.1

Controlling via RS-232

You can connect to the unit via a crossed RS-232 connection, using for example,

a PC. A crossed cable or null-modem is required as shown in method A and B

respectively. If a shielded cable is used, connect the shield to pin 5.

Method A (

Figure 4

)

—Connect the RS-232 9-pin D-sub port on the unit via a

crossed cable (only pin

2

to pin

3

, pin

3

to pin

2

, and pin

5

to pin

5

need be

connected) to the RS-232 9-pin D-sub port on the PC.

Note: There is no need to connect any other pins.

Figure 4: Crossed Cable RS-232 Connection

Hardware flow control is not required for this unit. In the rare case where a

controller requires hardware flow control, short pin 1 to 7 and 8, and pin 4 to 6 on

the controller side.

Method B (

Figure 5

)

—Connect the RS-232 9-pin D-sub port on the unit via a

straight (flat) cable to the null-modem adapter, and connect the null-modem

adapter to the RS-232 9-pin D-sub port on the PC. The straight cable usually

contains all nine wires for a full connection of the D-sub connector. Because the

null-modem adapter (which already includes the flow control jumpering described

1

2

6

3

7

4

8

5

9

1

2

6

3

7

4

8

5

9