Figure 9: rs-485 dip-switch default setting, Table 3: rs-485 dip-switch settings, Table 4: machine number dip-switch settings – Kramer Electronics VP-31KSi User Manual

Page 17: Figure 9, Table 3

Advertising
background image

Connecting the VP-31KSi 3x1 UXGA/Audio STEP-IN Switcher

13

Figure 9: RS-485 DIP-switch Default Setting

Table 3: RS-485 DIP-switch Settings

DIP-switch Number

Function

1, 2, 3

Machine number (see

Table 4

)

Default—All off (up), machine number 1

4

RS-485 Bus Termination

Default—Off (up)

DIP-switches 1, 2 and 3 determine the RS-485 machine number of the

VP-31KSi. When several VP-31KSi units are connected, the machine number

determines the unique identity of the VP-31KSi on the bus (see

Table 4

).

Note:

When using a stand-alone VP-31KSi unit, set the machine number to 1

(factory default)

When connecting more than one VP-31KSi, set the first machine (connected

via RS-232) to be machine number 1. The other VP-31KSi units must each

be set to a unique machine number between 2 and 8

Table 4: Machine Number DIP-switch Settings

Machine Number

1

2

3

1 (Default)

OFF

OFF

OFF

2

OFF

OFF

ON

3

OFF

ON

OFF

4

OFF

ON

ON

5

ON

OFF

OFF

6

ON

OFF

ON

7

ON

ON

OFF

8

ON

ON

ON

DIP-switch 4 sets the RS-485 bus termination of the VP-31KSi. Only the first and

last physical units on the RS-485 bus must be terminated, all others must be

unterminated. Moving the DIP-switch up turns the termination off (default),

moving the switch down turns the termination on.

5.6.2 Connecting and Controlling Multiple VP-31KSi Devices

You can daisy-chain up to eight VP-31KSi devices with operation via RS-232

from a PC or serial controller (see

Figure 10

).