Kramer protocol – Kramer Electronics VP-31KSi User Manual

Page 41

Advertising
background image

Kramer Protocol

37

Machine info commands

Read in/outs count INFO-IO?

INFO-IO: IN INPUTS_COUNT, OUT OUTPUTS_COUNT

Read max presets

count

INFO-PRST?

INFO-PRST: VID PRESET_VIDEO_COUNT, AUD

PRESET_AUDIO_COUNT

Reset configuration

to factory default

FACTORY

FACTORY RESULT

Identification commands

Command

Syntax

Response

Protocol Handshaking

#

CR

~OK CRLF

Read device model

MODEL?

MODEL MACHINE_MODEL

Read device serial number SN?

SN SERIAL_NUMBER

Read device firmware

version

VERSION?

VERSION MAJOR .MINOR .BUILD .REVISION

Set machine name

NAME MACHINE_NAME

NAME MACHINE_NAME RESULT

Read machine name

NAME?

NAME MACHINE_NAME

Reset machine name to

factory default*

NAME-RST

NAME-RST MACHINE_FACTORY_NAME RESULT

*Note: machine name not equal to model name. This name relevance for site viewer identification of specific machine or for

network using (with DNS feature on).

MACHINE_NAME = Up to 14 Alfa-Numeric chars.
*

Machine factory name = Model name + last 4 digits from serial number.

Set machine id number

MACH-NUM

MACHINE_NUMBER

MACH-NUM OLD_MACHINE_NUMBER

,NEW_MACHINE_NUMBER RESULT

* Response will send after machine number has been changed. So the replay with header will be:

NEW_MACHINE_NUMBER @

MACH-NUM OLD_MACHINE_NUMBER ,NEW_MACHINE_NUMBER OK

Network settings commands

Set IP Address

NET-IP IP_ADDRESS

NTIP

NET-IP IP_ADDRESS RESULT

Read IP Address

NET-IP?

NTIP?

NET-IP IP_ADDRESS

Read MAC Address

NET-MAC?

NTMC

NET-MAC MAC_ADDRESS

Set subnet mask

NET-MASK SUBNET_MASK

NTMSK

NET-MASK SUBNET_MASK RESULT

Read subnet mask

NET-MASK?

NTMSK?

NET-MASK SUBNET_MASK