Your RGBHV / Balanced Audio Matrix Switcher

11

Table 2: The RGBHV / Balanced Audio Matrix Switcher Rear Panel

Features

#

Feature

Function

14

TERM: 75 /TTL

Buttons

When pressed, the inputs are terminated with 75 loads. When released,

the load is >500

15

AUDIO INPUTS

1

Terminal

Block Connectors

Connect to the balanced stereo audio sources

16

AUDIO OUTPUTS

1

Terminal

Block Connectors

Connect to the balanced stereo audio acceptors

17 Ethernet Connector

Connects to the PC or other Serial Controller through computer networking

18

RS-485

Port

Pin G is for the Ground connection

2

; pins B (-) and A (+) are for RS-485

19

REMOTE IR

3.5mm Mini

Jack

Connect to an external IR receiver unit for controlling the machine via an IR

remote controller (instead of using the front panel IR receiver)

3

20 Power Connector with Fuse

AC connector, enabling power supply to the unit

21

FACTORY RESET

Button

Press to reset to factory default definitions

4

:

IP number 192.168.1.39
Mask – 255.255.255.0
Gateway – 192.168.1.1

22 Dipswitches

Dipswitches for setup of the unit (1, 2 and 3 are for setting the machine

number; 4 is for RS-485 bus termination; 5 is for Reply; 8 is for RS-485 PC

communication)

23

RS-232

9-pin D-sub Port

Connects to the PC or the remote controller

24

OUT

BNC Connectors

Connect to the video acceptors

25

INPUTS

BNC Connectors

Connect to the video sources

26

EXT./IN 1

Button

When pushed in selects an external sync from the external source; when

released selects the internal sync (inputted via the video input #1

connectors)

27

EXT. SYNC

BNC Connector

Connects to the external sync source


1 VP-88ETH has 8 inputs and 8 outputs; VP-84ETH has 8 inputs and 4 outputs; VP-82ETH has 8 inputs and 2 outputs;
VP-66ETH has 6 inputs and 6 outputs; VP-64ETH has 6 inputs and 4 outputs
2 The ground connection is sometimes connected to the shield of the RS-485 cable. In most applications, the ground is not
connected
3 Can be used instead of the front panel (built-in) IR receiver to remotely control the machine
4 Turn the machine OFF, then turn the machine ON while pressing the FACTORY RESET button. The unit powers up and
loads its memory with the factory default definitions