2 preview and program input and output settings, Figure 13: input mode setting screen, Figure 13 – Kramer Electronics VP-747 User Manual

Page 36

Advertising
background image

VP-747 - Operating the VP-747

31

8.1.2

Preview and Program Input and Output Settings

Figure 13

defines the input Mode Setting:

Figure 13: Input Mode Setting Screen

Input Mode Functions
Setting

Function

Range

Default

Custom Input

Set custom values

Custom 1 to 4

HT

Horizontal Total

1344

HW

Horizontal sync pulse width

136

HS

Horizontal active start point

296

HA

Horizontal active region

1024

HP

Horizontal polarity

VT

Vertical Total

806

VW

Vertical sync pulse width

6

VS

Vertical active start point

35

VA

Vertical active region

768

VP

Vertical polarity

OCLK

Output clock

65

Enable

off

Save

Click to save settings

N/A