1 using the setup menu, 2 setup menu—3: outxx=>off, turning an output off, Using the setup menu – Kramer Electronics VS-1616D User Manual

Page 30: Setup menu—3: outxx=>off, turning an output off

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Using the Configuration Menus

26

8.1 Using the Setup Menu

The Setup Menu provides access to settings that are regularly changed and

comprises the following options:

1: inXX=>ALL, switching one input to all outputs (see

Section 8.1.1

3: outXX=OFF, turning off an output (see

)

Section 8.1.2

7: EDID, assignment to an output (see

)

Section 8.1.3

9: Delay setting for an output (see

)

Section 8.1.4

4: store setup XX, storing the setup in a preset (see

)

Section 8.1.5

6: recall setup XX, recalling a preset (see

)

Section 8.1.6

8.1.1 Setup Menu—1: inXX=>ALL, Switching one Input to all Outputs

)

This option switches one input to all outputs.
To switch one input to all outputs:

1. Press MENU.

The Setup Menu options are displayed.

2. Press 1 (ALL) on the numeric keypad (see

Figure 2

).

The following is displayed:

in__ => ALL

3. Using the numeric keys, enter the input to be switched to all outputs.

The TAKE button flashes.

4. Press TAKE.

The selected input is switched to all outputs.

The display reverts to the output/input display showing that the selected input

is switched to all outputs.

8.1.2 Setup Menu—3: outXX=>OFF, Turning an Output Off

This option turns an output off.
To turn an output off:

1. Press MENU.

The Setup Menu options are displayed.

2. Press 3 (OFF) on the numeric keypad (see

Figure 2

).

The following is displayed:

out__ => OFF

3. Using the numeric keys, enter the output to be turned off.

The TAKE button flashes.

4. Press TAKE.

The selected output is turned off.

The display reverts to the output/input display showing that the selected

output is turned off with the input being blank.

Advertising