2 resetting to the default edid, 3 storing and recalling a switching setting, Resetting to the default edid – Kramer Electronics VS-42HN User Manual

Page 15: Storing and recalling a switching setting

Advertising
background image

12

VS-42HN - Operating the VS-42HN 4x2 HDMI Matrix Switcher

4. For each input, select the output from which it will acquire the EDID, or

deselect it so it will reset to the default EDID value.

For example, to copy the EDID of output 2 to input 3, press the INPUT

SELECTOR button 3 on the TO OUTPUT 2 line.

5. Press the LOCK button.

The LOCK button and the INPUT buttons flash until the EDID is acquired.

6.2

Resetting to the Default EDID

To reset to the default EDID do either of the following:

Disconnect the outputs and repeat the steps listed in

Section

6.1

Press the input where the default EDID is to be stored to disconnect it from

the output

6.3

Storing and Recalling a Switching Setting

You can use the STO and RCL buttons to store the current setup and then recall it.

The VS-42HN stores only one setting in memory. Storing a new setting
overwrites the previous one.

To store a setting:

1. Press the STO button.

The STO button illuminates and the:

Currently selected input buttons illuminate

The selected Input buttons in the current configuration flash

For example, if both outputs are currently disconnected, both OFF buttons

will be illuminated and the current setting input buttons (for example, INPUT

1 to OUTPUT 1 and INPUT 3 to OUTPUT 2) flash.

2. Set the machine to the desired setting.

For example, press INPUT SELECTOR button 3 on the TO OUTPUT 1 line

and INPUT SELECTOR button 1 on the TO OUTPUT 2 line.

These buttons flash.

i