2 resetting to the default edid, 3 storing and recalling a switching setting, Resetting to the default edid – Kramer Electronics VS-42HN User Manual
Page 15: Storing and recalling a switching setting

12
VS-42HN - Operating the VS-42HN 4x2 HDMI Matrix Switcher
4. For each input, select the output from which it will acquire the EDID, or
deselect it so it will reset to the default EDID value.
For example, to copy the EDID of output 2 to input 3, press the INPUT
SELECTOR button 3 on the TO OUTPUT 2 line.
5. Press the LOCK button.
The LOCK button and the INPUT buttons flash until the EDID is acquired.
6.2
Resetting to the Default EDID
To reset to the default EDID do either of the following:
Disconnect the outputs and repeat the steps listed in
Section
Press the input where the default EDID is to be stored to disconnect it from
the output
6.3
Storing and Recalling a Switching Setting
You can use the STO and RCL buttons to store the current setup and then recall it.
The VS-42HN stores only one setting in memory. Storing a new setting
overwrites the previous one.
To store a setting:
1. Press the STO button.
The STO button illuminates and the:
Currently selected input buttons illuminate
The selected Input buttons in the current configuration flash
For example, if both outputs are currently disconnected, both OFF buttons
will be illuminated and the current setting input buttons (for example, INPUT
1 to OUTPUT 1 and INPUT 3 to OUTPUT 2) flash.
2. Set the machine to the desired setting.
For example, press INPUT SELECTOR button 3 on the TO OUTPUT 1 line
and INPUT SELECTOR button 1 on the TO OUTPUT 2 line.
These buttons flash.
i