8 default communication parameters, Default communication parameters, 8default communication parameters – Kramer Electronics VS-42HN User Manual

Page 22

Advertising
background image

VS-42HN - Default Communication Parameters

19

8

Default Communication Parameters

RS-232

Protocol 2000 (Default)

Protocol 3000

Baud Rate

9600

Baud Rate

9600

Data Bits

8

Data Bits

8

Stop Bits

1

Stop Bits

1

Parity

None

Parity

None

Command Format

HEX

Command Format

ASCII

Example (Output
1 to Input 1)

0x01, 0x81, 0x81, 0x81

Example (Output 1 to
Input 1)

#VID1>1<CR>

Switching Protocol

P2000

–> P3000

P3000

–> P2000

Command

0x38, 0x80, 0x83, 0x81

Command

#P2000<CR>

Front Panel

On the TO OUTPUT 1 row,
press input buttons 1 and 3
at the same time

Front Panel

On the TO OUTPUT 1 row,
press input buttons 1 and 2
at the same time

Ethernet

IP Address

192.168.1.39

TCP Port

5000 or 10001 or 50000

Subnet Mask

255.255.255.0

UDP Port

50000